The Alarm.com ADC-EPB-BC2.1-GE is a stationary emergency button with an Interlogix/Qolsys transmitter for secure independent home care and senior living. The ADC-EPB-BC2.1-GE emergency button grants caregivers real-time insight into each client's current conditions as well as potential emergency problems.

This device requires an Alarm.com account, your Alarm.com partner will need to work with you to add Alarm.com devices to your account.

Alarms247 offers DIY monitoring packages to support these devices.

Product Specifications:

  • Enclosure: 4.75 in. x 2.25 in. (Diameter x Depth) Black, ABS plastic base with slip-resistant feet and 3 x AAA battery housing for optional audible message on button press Red, ABS plastic, spring-loaded push button
  • Electronic Signaling: Battery-powered filter circuit with integrated 319.5 MHz (crystal-controlled) Interlogix/Qolsys-compatible transmitter with 64-minute supervisory interval
  • Sensing Interface: Filtered, normally open (i.e. when not pressed), momentary contact switch
  • Battery Life: Replaceable 3x AAA battery: 2+ years

Product Programming:

  • Use the Alarm.com AirFX "Add a Sensor" page or the panel interface to add the button to the account. Set the "New Sensor Information" as shown in the chart. For enrolling the device at the panel, the sensor can be tampered with by pressing the button within the first two seconds that the On/Off switch is set to the "On" position. Please note that group 4 should be used if the button is used to signal an emergency. Group 40 or group 27 can be used if the button is not being used to signal an emergency.
  • After the sensor is added to the system, change the sensor type to "Push Button." From the Equipment page of the Dealer Website click Change to the right of the sensor's name. Select the "Change Sensor Type" action, and update the new sensor type to "Push Button."
    • Sensor ID Select an unused ID
    • Zone Definition 4 (Emergency) or 40 (Non-Emergency)
    • Sensor Name Any
    • DL Code On the bottom of the sensor

Product Installation:

Locate the sensor within 100 feet of the base station. Ensure that the On/Off switch on the base of the button is set to the "On" position. The sensor can be mounted using the included mounting plate and mounting hardware or simply place the sensor on a flat surface in a visible location.

 

 

 